1. Home
  2. permeable cooling

Cooling-induced permeability enhancement for networks of

$ 15.99

4.9 (389) In stock

Recent researches have proposed the use of enhanced geothermal system reservoirs consisting of dense networks of microfractures, created by hydraulic and/or thermal fracturing in superhot/supercritical geothermal environments, because of their suitability for thermal energy harvesting. During fracturing and energy extraction, the fracture networks are exposed to cooling due to the injection of cold fluid into the reservoirs. Previous studies showed such cooling enhanced reservoir permeability in conventional geothermal environments. However, the cooling may result in a higher risk of seismicity, owing to decreased normal stress on the fractures. Nevertheless, it is unclear whether cooling-induced permeability enhancement and a higher risk of seismicity occurs within networks of microfractures which consist of numerous interconnected microfractures at various orientations to the in situ triaxial stress. Thus, no dominant fractures have the possibility to cause permeability enhancement/induced seismicity. In this study, results are presented for borehole cooling experiments on a dense network of microfractures in granite, at 400 °C, under true triaxial stress. Permeability and acoustic emissions were measured with decreases in borehole temperature (up to ~ 90 °C). Results showed that permeability increased with increasing temperature drop at relatively low stress levels (15 and 20 MPa). The permeability enhancement occurred without intensive failure, and was reversible. However, permeability was almost constant at a higher stress level (65 MPa). Results showed that permeability enhancement required a thermal stress equivalent to the mean stress, so that the normal stress was reduced to near-zero, for a considerable amount of the microfractures. Additionally, the permeability of dense microfracture networks can be increased by cooling primarily through thermo-elastic deformation (without intensive failure), which may be useful to compensate for the reduction in injectivity due to cooling-induced fluid property changes.

Temperature logs T-28, T-30 and T-32 measured in well H-26 at 0

The risks of long-term re-injection in supercritical geothermal

Aperture PDFs for various in-situ stress cases at selected four

Curve of the AR change of high-temperature granite after a cooling

Spatial distribution of fracture apertures for various in-situ

Schematic representation of flow-induced microfracturing

Velocity PDFs for various in-situ stress cases at time at = 1 a

Noriaki Watanabe — Tohoku University

PDF) A laboratory study of hydraulic fracturing at the brittle

Optical microphotographs of a thin cross-section of the horizontal

Articles Geothermal Energy

Permeability enhancement by CO2 injection and chelating agent

PDF) Reduction of Permeability in Granite at Elevated Temperatures

Changes in differential pressure and corresponding permeability in